Printed in U.S.A. Manual No. 197523GS Revision D (06/05/2007)6200 Watt Portable GeneratorOperator’s ManualBRIGGS & STRATTON POWER PRODUCTS GROU

Strona 2

10 BRIGGSandSTRATTON.COMFeatures and ControlsRead this Operator’s Manual and safety rules before operating your generator.Compare the illustrations wi

Strona 3 - Table of Contents

11Cord Sets and ReceptaclesUse only high quality, well-insulated, grounded extensioncords with the generator’s 120 Volt duplex receptacle.Inspect exte

Strona 4 - Operator Safety

Battery Float ChargerUse battery float charger jack to keep the starting batterycharged and ready for use. Battery charging should be donein a dry loc

Strona 5

13OperationStarting the EngineIMPORTANT: Always unplug the battery float charger beforestarting the generator.Disconnect all electrical loads from the

Strona 6

Connecting Electrical Loads1. Let engine stabilize and warm up for a few minutesafter starting.2. Plug in and turn on the desired 120 and/or 240 Volt

Strona 7 - Assembly

15Don’t Overload GeneratorCapacityYou must make sure your generator can supply enoughrated (running) and surge (starting) watts for the items youwill

Strona 8 - Attach Negative Battery Cable

16 BRIGGSandSTRATTON.COMMaintenanceMaintenance ScheduleFollow the hourly or calendar intervals, whichever occurs first. More frequent service is requi

Strona 9 - Generator Location

17• Use a soft bristle brush to loosen caked on dirt or oil.• Use a vacuum cleaner to pick up loose dirt and debris.Battery MaintenanceOther than floa

Strona 10 - Features and Controls

3. Clean area around oil drain plug (A). The oil drain plugis located at base of engine, opposite carburetor.4. Remove oil drain plug and drain oil co

Strona 11 - NEMA L14-30

191. To remove muffler heat shield (A) from muffler (B),remove four screws that connect guard to mufflerbracket.2. Remove four screws that attach spar

Strona 12 - Battery Float Charger

2 BRIGGSandSTRATTON.COMBriggs & Stratton Power Products Group, LLC900 North ParkwayJefferson, WI 53549Copyright © 2007 Briggs & Stratton Powe

Strona 13 - Operation

20 BRIGGSandSTRATTON.COMStorageThe generator should be started at least once every sevendays and allowed to run at least 30 minutes. If this cannot be

Strona 14 - Stopping the Engine

21TroubleshootingProblem Cause CorrectionEngine is running, but no ACoutput is available.1. One of the circuit breakers is open.2. Fault in generator.

Strona 15 - Don’t Overload Generator

22 BRIGGSandSTRATTON.COMWarrantiesEmissions Control System WarrantyBriggs & Stratton Corporation (B&S), the California AirResources Board (CAR

Strona 16 - Maintenance

232. Length of CoverageB&S warrants to the initial owner and each subsequentpurchaser that the Warranted Parts shall be free fromdefects in materi

Strona 17 - Engine Maintenance

24 BRIGGSandSTRATTON.COMBRIGGS & STRATTON POWER PRODUCTS GROUP, LLC PORTABLE GENERATOR OWNER WARRANTY POLICYLIMITED WARRANTYBriggs & Stratton

Strona 19

26 BRIGGSandSTRATTON.COMPortable GeneratorPower Ratings: The gross power rating for individual gas engine models is labeled in accordance with SAE (So

Strona 20

Table of ContentsOperator Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Equipment Description. . . . . . . . . . . . . . .

Strona 21 - Troubleshooting

Operator SafetyEquipment DescriptionRead this manual carefully and become familiarwith your generator. Know its applications, itslimitations and any h

Strona 22 - Warranties

5WARNINGThe engine exhaust from this product containschemicals known to the State of California to causecancer, birth defects, or other reproductive h

Strona 23 - Emission Information

6 BRIGGSandSTRATTON.COMWARNINGContact with muffler area can result in seriousburns.Exhaust heat/gases can ignite combustibles,structures or damage fue

Strona 24 - 24 BRIGGSandSTRATTON.COM

7AssemblyYour generator requires some assembly and is ready for useafter it has been properly serviced with the recommendedfuel and oil.If you have an

Strona 25

Add Engine Oil1. Place generator on a flat, level surface.2. Clean area around oil fill and remove yellow oil fill cap.NOTE: See the section Oil to re

Strona 26 - Portable Generator

95. Verify that connections to battery and generator aretight and secure.NOTE: Charge prior to use following the instructions in thesection Battery Fl