Stopping
Depress the metal tab mounted on the engine head next to the spark plug against
the plug and hold until the engine stops.
Before extended storage-when the generator is not going to be used for several
months, certain precautions must be taken to ensure the fuel doesn't deteriorate
and clog the fuel system.
1.
Remove remaining fuel from the fuel tank by siphoning or pumping it empty.
2. Start the engine and allow to run until all the fuel in the carburetorlfuel tank has
been used up and the engine stops.
Refueling
WARNING
A
NEVER refuel a running engine or allow fuel to be spilled
on a hot engine or muffler. Let the engine cool at least
2
minutes before attempting to refuel. NEVER refuel an
engine near an open flame or spark source. NEVER refuel
indoors. NEVER run unit indoors.
Always use clean, fresh fuel blended for the proper season. Winter fuel will, vaporlock
when used in the summer and summer fuel will cause hard starting in the winter.
Gasoline which has been stored for months loses its volatile properties due to
evaporation, leaving behind a varnish like residue. This residue, although burnable,
will clog the fuel system and cause sticking valves and carbon build up after a short
time.
Wipe up any spilled fuel and allow sufficient time for all the residue to completely
evaporate before attempting to start the engine.
YOUR RESPONSIBILITIES
This unit has been designed and thoroughly tested to help insure a long service life.
It Is YOUR RESPONSIBILITY to perform the routine maintenance necessary to keep
the engine and generator warranty in force. FAILURE to PERFORM ROUTINE
MAINTENANCE may result in an expensive and unnecessary PREMATURE
NON-
WARRANTY FAILURE.
Please use the following maintenance chart as a guideline for your preventative
maintenance schedule.
Check
Oil level every five
(5)
hours.
Fuel level daily.
Air cleaner weeklylmore often under dirty conditions.
Change
Oil after the first two
(2)
hours and every
25
hours thereafter.
CleanlReplace
Unit-keep the unit clean and remove dirt, grease and debris from the air inlets on
the engine and generator.
Air cleaner yearly under normal conditions, more often under extremely dirty
conditions.
Spark plug periodically or once a year depending on usage.